4 dB rule - DTX CableAnalyzer | Fluke Networks

Base de connaissances

 Ko Accueil   >  Test de câblage cuivre   >  DTX CableAnalyzer™

Règle de 4 dB - DTX CableAnalyzer

A YouTube video explaining how this this works is also available from here.  

This is applicable to the following cabling standards only:
 

  • ISO/IEC 11801
  • EN 50173
  • Aus/NZ
  • JIS

When the Insertion Loss is less than 4,0 dB at the frequency point where the measurement is made, then the measurement is ignored and not evaluated against the selected Test Limit/Cabling Standard in the DTX CableAnalyzer. Cela est souvent appelé la règle des 4 dB. It is not applied in the North American TIA Cabling Standards. Only certain test parameters and configurations will have the 4 dB rule. The tables below indicate which link  definitions and test parameters have the 4 dB rule applied to them. As an aid, the other rules are also listed.

Test Parameter

Classe D
Perm. Liaison

Classe E
Perm. Liaison

Class EA
Perm. Liaison

Class F
Perm. Liaison

Classe FA
Perm. Liaison

SUIVANT

PS NEXT

ACR-N

PS ACR-N

ACR-F

 

 

PS ACR-F

 

 

Perte par réflexion (RL)

         
 
 

Test Parameter

Classe D
Canal

Classe E
Canal

Class EA
Canal

Class F
Canal

Classe FA
Canal

SUIVANT

PS NEXT

ACR-N

 

 

     

PS ACR-N

         

ACR-F

 

 

PS ACR-F

 

 

Perte par réflexion (RL)

         

 
On a short link, the Insertion Loss may never reach 4,0 dB. Si cela devait se produire, la mesure serait alors ignorée ou comme le dit la norme de câblage, « enregistrée à titre indicatif uniquement ». Si cela devait se produire avec votre CableAnalyzer DTX, vous verriez apparaître un "i" à côté du résultat résumé pour ce paramètre de test. Dans le logiciel LinkWare, le résultat serait enregistré en affichant S/O. Un exemple est représenté ci-dessous :
 

            Le logiciel LinkWare a mis en évidence un résultat du test S/O    
 

Des préoccupations font normalement suite à un résultat qui a une marge négative. In this example we see the NEXT margin was -9,7 dB. A negative margin is normally associated with a FAIL, but because the entire link never exceeded 4,0 dB Insertion Loss, it's not a FAIL. Further confusion lies in that the North American ANSI/TIA/-568-C.0 cabling standard does not have this 4 dB rule. If you were to test the same link above with the same DTX CableAnalyzer, but using the North American Standard TIA Cat 5e Perm. Link, your result would be a FAIL.

            Autotest with Fail Result
 
Please make sure you have agreed in a Test Limit, in writing, before the project starts.
 
Let's review in detail how this works by looking at another example test result on the DTX CableAnalyzer.

An ISO11801 PL Max Class D AUTOTEST was run on a short 6,0 m installed link, giving the following result:
 
            Autotest with Pass Result
 
Looks normal. Let's take a look at the NEXT result in a little more detail:
 
            DTX CableAnalyzer NEXT Result

Vous constaterez que la ligne de limite a deux couleurs, noir et rouge. Les normes de câblage n'exigent pas que le fabricant du testeur de câbles affiche où la règle 4 dB est appliquée à l'utilisateur, mais seulement qu'elle soit appliquée. Cependant, le DTX CableAnalyzer indiquera où la règle 4 dB a été appliquée en changeant la couleur de la ligne de limite. If the limit line is black, the Insertion Loss was less than 4,0 dB. Si la ligne de limite est rouge, la perte d'insertion était de 4,0 dB ou supérieure. So for this Pair 1,2-4,5 the NEXT is not evaluated below 84,8 MHz. Let's take a quick look at the Insertion Loss for Pair 4,5:
  
            Résultat de perte d'insertion sous DTX CableAnalyzer
 
As you can see, the Insertion Loss reached 4,0 dB at 84,8 MHz, as previously indicated in the NEXT Pair 1,2-4,5 graph above. NEXT contains two pairs. So which Insertion Loss pair do we use to implement the 4 dB rule? The disturbed pair is used for evaluation purposes. So if the worst case NEXT Pair was 1,2-7,8 then the DTX CableAnalyzer would use the Insertion Loss values from Pair 7,8 to determine where the 4 dB rule is implemented.

As previously mentioned, if the link is particularly short, then the Insertion Loss may never reach 4,0 dB and the entire NEXT result is "ignored". Examinons de plus près le premier exemple où le résultat du test était de :
 
            Ignored NEXT Result Screen

 
Looking at the worst case NEXT result, we see the entire limit line is black, suggesting that the Insertion Loss for Pair 4,5 never reached 4,0 dB: 
 
            Worst Case NEXT Result Screen
 
 
En regardant la perte d'insertion pour la paire : 4,5
 
            Résultat de perte d'insertion sous 4 dB
 
Nous voyons que l'insertion n'a en effet jamais atteint 4,0 dB, de sorte que la mesure entière n'est pas évaluée par rapport à la ligne de limite (ignorée) et enregistrée en tant qu'information "i" uniquement. Si ce résultat a été téléchargé vers le logiciel LinkWare, le rapport montrerait S/O pour cette mesure :
 
            Highlighted N/A Measurement
 
Aucune autre action n'est requise de la part de l'installateur. Il s'agit d'un résultat valide conforme aux normes.

Auteur : A. Young